What is partial muting and how do I set it up?
Partial muting lets you limit the muting function to several well-defined beams. You can enable muting only for the beams that are interrupted by the passage of the material (such as lower pallets at the end of the product cycle). The remaining beams, however, can be kept active to protect the hazardous zone. Partial muting also avoids the possibility of climbing onto the object without being detected.
Muting is only available on XUSL4MA models and must be configured through SoMute software.